Loading EveryPlace content…
Loading EveryPlace content…
State license
Active
MO DHSS
Google reviews
Not available
Public reviews not linked
Size & payment
70 residents
Confirm pricing & payment
Public records for this community are limited. Use the checklist below when you call or visit to confirm pricing, services, and openings.
| Monthly cost | Not published | Ask for the full monthly cost, including care fees and one-time charges. |
|---|---|---|
| Payment options | Ask directly | Payment details are not confirmed in our records. Ask about private pay, long-term care insurance, veterans benefits, and Medicaid waivers. |
| Size & availability | 70 residents | We don't publish live openings. Ask about current availability, waitlist length, and move-in timing. |
| Care & support | Assisted livingMemory care certified | Usually offers housing and help with everyday tasks, such as bathing and dressing. What to confirm about care levelsThis describes the licensed category. Ask how care plans adjust if mobility, nursing, or memory needs change over time. Read the family care guide → |
State licensing
9inspections
14deficiencies listed
No deficiencies reported
View official state report (opens in a new tab)
No state licensure deficiencies were cited during this inspection.
8 deficiencies reported
View official state report (opens in a new tab)
8 state licensure deficiency citation(s) recorded.
minorCorrected Apr 30, 2024
Exits, Stairways, and Fire Escapes. (D) An " area of refuge " shall have- 1. An area separated by one- (1-) hour rated smoke walls, from the remainder of the building. This area must have direct access to the exit stairway or access the stair through a section of the corridor that is separated by smoke walls from the remainder of the building. This area may include no more than two (2) resident rooms; 2. A two- (2-) way communication or intercom system with both visible and audible signals between the area of refuge and the bottom landing of the exit stairway, attendants ' work area, or other primary location as designated in the written plan for fire drills and evacuation; 3. Instructions on the use of the area during emergency conditions that are located in the area of refuge and conspicuously posted adjoining the communication or intercom system; 4. A sign at the entrance to the room that states " AREA OF REFUGE IN CASE OF FIRE " and displays the international symbol of accessibility; 5. An entry or exit door that is at least a one and three-fourths inch (1 3/4") solid core wood door or has a fire protection rating of not less than twenty (20) minutes with smoke seals and positive latching hardware. These doors shall not be lockable; 6. A sign conspicuously posted at the bottom of the exit stairway with a diagram showing each location of the areas of refuge; 7. Emergency lighting for the area of refuge; and 8. The total area of the areas of refuge on a floor shall equal at least twenty (20) square feet for each resident who is blind or requires the use of a wheelchair or walker housed on the floor. II
minorCorrected Apr 30, 2024
Protection from Hazards. (I) In facilities whose plans were approved or which were initially licensed after December 31, 1987, for more than twenty (20) beds and all facilities licensed after August 28, 2007, each smoke section shall be separated by one- (1-) hour fire-rated smoke partitions. The smoke partitions shall be continuous from outside wall-to-outside wall and from floor-to-floor or floor-to-roof deck. All doors in this wall shall be at least twenty- (20-) minute fire-rated or its equivalent, self-closing, and may be held open only if the door closes automatically upon activation of the complete fire alarm system. II
minorCorrected Apr 30, 2024
Complete Fire Alarm Systems. (C) All facilities shall test and maintain the complete fire alarm system in accordance with NFPA 72, 1999 edition. I/II
minorCorrected Apr 30, 2024
Trash and Rubbish Disposal. (A) Only metal or UL- or FM-fire-resistant rated wastebaskets shall be used for trash. II
minorCorrected Apr 30, 2024
Protection from Hazards. (G) All doors providing separation between floors shall have a self-closing device attached. If the doors are to be held open, electromagnetic hold-open devices shall be used that are interconnected with either an individual smoke detector or a complete fire alarm system. II
minorCorrected Apr 30, 2024
Sprinkler Systems. (F) All facilities shall have inspections and written certifications of the approved sprinkler system completed by an approved qualified service representative in accordance with NFPA 25, 1998 edition. The inspections shall be in accordance with the provisions of NFPA 25, 1998 edition, with certification at least annually by a qualified service representative. I/II
minorCorrected Apr 30, 2024
Exits, Stairways, and Fire Escapes. (E) If it is necessary to lock exit doors, the locks shall not require the use of a key, tool, special knowledge, or effort to unlock the door from inside the building. Only one (1) lock shall be permitted on each door. Delayed egress locks complying with section 7.2.1.6.1 of the 2000 edition NFPA 101 shall be permitted, provided that not more than one (1) such device is located in any egress path. Self-locking exit doors shall be equipped with a hold-open device to permit staff to reenter the building during the evacuation. I/II
minorCorrected Apr 30, 2024
Complete Fire Alarm Systems. (A) All facilities shall have a complete fire alarm system installed in accordance with NFPA 101, Section 18.3.4, 2000 edition. The complete fire alarm shall automatically transmit to the fire department, dispatching agency, or central monitoring company. The complete fire alarm system shall include visual signals and audible alarms that can be heard throughout the building and a main panel that interconnects all alarm-activating devices and audible signals. Manual pull stations shall be installed at or near each required attendant ' s station and each required exit. I/II 1. For facilities with a sprinkler system in accordance with NFPA 13, 1999 edition, smoke detectors interconnected to the complete fire alarm system shall be installed in all corridors and spaces open to corridors. Smoke detectors shall be no more than thirty feet (30') apart with no point on the ceiling more than twenty-one feet (21') from a smoke detector. I/II
1 deficiency reported
View official state report (opens in a new tab)
1 state licensure deficiency citation(s) recorded.
minorCorrected Feb 15, 2024
Each room or ward in which residents are housed or to which residents have reasonable access shall be capable of being heated to not less than eighty degrees Fahrenheit (80°F) under all weather conditions. Temperature shall not be lower than sixty-eight degrees Fahrenheit (68°F) and the reasonable comfort needs of individual residents shall be met. I/II
1 deficiency reported
View official state report (opens in a new tab)
1 state licensure deficiency citation(s) recorded.
minorCorrected Jan 29, 2024
In newly licensed facilities or if a new heating system is installed in an existing licensed facility, the heating of the building shall be restricted to steam, hot water, permanently installed electric heating devices or a warm air system employing central heating plants with installation such as to safeguard the inherent fire hazard, or approved installation of outside wall heaters which bear the approved label of the American Gas Association or National Board of Fire Underwriters. The foregoing requirements are applicable to residential care facilities. In assisted living facilities, the heating of the building shall be restricted to steam, hot water, permanently installed electric heating devices or a warm air system employing central heating plants with installation such as to safeguard the inherent fire hazard, or approved installation of outside wall heaters which bear the approved label of the American Gas Association or National Board of Fire Underwriters. For all facilities, oil or gas heating appliances shall be properly vented to the outside and the use of portable heaters of any kind is prohibited. If approved wall heaters are used, adequate guards shall be provided to safeguard residents. I/II
1 deficiency reported
View official state report (opens in a new tab)
1 state licensure deficiency citation(s) recorded.
minorCorrected Dec 15, 2023
The administrator shall develop and implement a safe and effective system of medication control and use, which assures that all residents ' medications are administered by personnel at least eighteen (18) years of age, in accordance with physicians ' instructions using acceptable nursing techniques. The facility shall employ a licensed nurse eight (8) hours per week for every thirty (30) residents to monitor each resident ' s condition and medication. Administration of medication shall mean delivering to a resident his or her prescription medication either in the original pharmacy container, or for internal medication, removing an individual dose from the pharmacy container and placing it in a small cup container or liquid medium for the resident to remove from the container and self-administer. External prescription medication may be applied by facility personnel if the resident is unable to do so and the resident ' s physician so authorizes. All individuals who administer medication shall be trained in medication administration and, if not a physician or a licensed nurse, shall be a certified medication technician or level I medication aide. I/II
2 deficiencies reported
View official state report (opens in a new tab)
2 state licensure deficiency citation(s) recorded.
minorCorrected Oct 2, 2023
The facility shall screen residents and staff for tuberculosis as required for long-term care facilities by 19 CSR 20-20.100. II
minorCorrected Oct 2, 2023
Protective oversight shall be provided twenty-four (24) hours a day. For residents departing the premises on voluntary leave, the facility shall have, at a minimum, a procedure to inquire of the resident or resident ' s guardian of the resident ' s departure, of the resident ' s estimated length of absence from the facility, and of the resident ' s whereabouts while on voluntary leave. I/II
1 deficiency reported
View official state report (opens in a new tab)
1 state licensure deficiency citation(s) recorded.
minorCorrected Nov 7, 2022
Protective oversight shall be provided twenty-four (24) hours a day. For residents departing the premises on voluntary leave, the facility shall have, at a minimum, a procedure to inquire of the resident or resident ' s guardian of the resident ' s departure, of the resident ' s estimated length of absence from the facility, and of the resident ' s whereabouts while on voluntary leave. I/II
No deficiencies reported
View official state report (opens in a new tab)
No state licensure deficiencies were cited during this inspection.
No deficiencies reported
View official state report (opens in a new tab)
No state licensure deficiencies were cited during this inspection.
Neighborhood & resident support
Nearest hospital
Mercy Hospital Springfield
3.3 mi · Springfield, MO · Medicare 3/5 ★
FEMA hazard risk
Free resident advocacy
Missouri Long-Term Care Ombudsman Program
VA & dialysis access
Fayetteville AR VA Medical Center
86.6 mi · Fayetteville, AR · VA 5/5 ★
3.0 mi · 2/5 ★ · Home dialysis
Specialists within 15 mi
Environment & mobility
County demographics
Call & tour checklist
Check off questions as you call or tour. Your progress stays private in this browser.
Verification & public records
Verify licensing, ratings, and inspection reports directly with each official source.
EveryPlace is an independent research directory. Information is compiled from public Medicare.gov, state licensing, Google Places, and street-level imagery sources. Some summaries, suggested questions, and pricing notes are AI-generated or AI-assisted and may contain errors or omissions. We do not accept payment for placement. Confirm all details directly with the community and official sources. Research Policy.
Keep exploring