Loading EveryPlace content…
Loading EveryPlace content…

State license
Active
MO DHSS
Google reviews
Not available
Public reviews not linked
Size & payment
26 residents
Confirm pricing & payment
Public records for this community are limited. Use the checklist below when you call or visit to confirm pricing, services, and openings.
| Monthly cost | Not published | Ask for the full monthly cost, including care fees and one-time charges. |
|---|---|---|
| Payment options | Ask directly | Payment details are not confirmed in our records. Ask about private pay, long-term care insurance, veterans benefits, and Medicaid waivers. |
| Size & availability | 26 residents | We don't publish live openings. Ask about current availability, waitlist length, and move-in timing. |
| Care & support | Assisted living | Usually offers housing and help with everyday tasks, such as bathing and dressing. What to confirm about care levelsThis describes the licensed category. Ask how care plans adjust if mobility, nursing, or memory needs change over time. Read the family care guide → |
State licensing
12inspections
11deficiencies listed
No deficiencies reported
View official state report (opens in a new tab)
No state licensure deficiencies were cited during this inspection.
No deficiencies reported
View official state report (opens in a new tab)
No state licensure deficiencies were cited during this inspection.
No deficiencies reported
View official state report (opens in a new tab)
No state licensure deficiencies were cited during this inspection.
5 deficiencies reported
View official state report (opens in a new tab)
5 state licensure deficiency citation(s) recorded.
minorCorrected Jun 18, 2024
Sprinkler Systems. (B) Facilities that have a sprinkler system installed prior to August 28, 2007, shall inspect, maintain, and test these systems in accordance with the requirements that were in effect for such facilities on August 27, 2007. I/II
minorCorrected Jun 18, 2024
Protection from Hazards. (A) In assisted living facilities and residential care facilities licensed on or after November 13, 1980, for more than twelve (12) beds, hazardous areas shall be separated by construction of at least a one- (1-) hour fire-resistant rating. In facilities equipped with a complete fire alarm system, the one- (1-) hour fire separation is required only for furnace or boiler rooms. Hazardous areas equipped with a complete sprinkler system are not required to have this one- (1-) hour fire separation. Doors to hazardous areas shall be self-closing and shall be kept closed unless an electromagnetic hold-open device is used which is interconnected with the fire alarm system. When the sprinkler option is chosen, the areas shall be separated from other spaces by smoke-resistant partitions and doors. The doors shall be self-closing or automatic-closing. Facilities formerly licensed as residential care facility I or II, and existing prior to November 13, 1980, shall be exempt from this requirement. II
minorCorrected Jun 18, 2024
Trash and Rubbish Disposal. (A) Only metal or UL- or FM-fire-resistant rated wastebaskets shall be used for trash. II
minorCorrected Jun 18, 2024
Rooms shall be neat, orderly and cleaned daily. II/III
minorCorrected Jun 18, 2024
If extension cords are used, they must be Underwriters ' Laboratory (UL)-approved or shall comply with other recognized electrical appliance approval standards and sized to carry the current required for the appliance used. Only one (1) appliance shall be connected to one (1) extension cord and only two (2) appliances may be served by one (1) duplex receptacle. If extension cords are used, they shall not be placed under rugs, through doorways or located where they are subject to physical damage. II/III
No deficiencies reported
View official state report (opens in a new tab)
No state licensure deficiencies were cited during this inspection.
No deficiencies reported
View official state report (opens in a new tab)
No state licensure deficiencies were cited during this inspection.
3 deficiencies reported
View official state report (opens in a new tab)
3 state licensure deficiency citation(s) recorded.
minor
Trash and Rubbish Disposal. (A) Only metal or UL- or FM-fire-resistant rated wastebaskets shall be used for trash. II
minor
In facilities that are constructed or have plans approved after July 1, 2005, electrical wiring shall be installed and maintained in accordance with the requirements of the National Electrical Code, 1999 edition, National Fire Protection Association, Inc., incorporated by reference, in this rule and available by mail at One Batterymarch Park, Quincy, MA 02269, and local codes. This rule does not incorporate any subsequent amendments or additions to the materials incorporated by reference. Facilities built between September 28, 1979 and July 1, 2005 shall be maintained in accordance with the requirements of the National Electrical Code, which was in effect at the time of the original plan approval and local codes. This rule does not incorporate any subsequent amendments or additions. In facilities built prior to September 28, 1979, electrical wiring shall be maintained in good repair and shall not present a safety hazard. All facilities shall have wiring inspected every two (2) years by a qualified electrician. II/III
minor
Oxygen storage shall be in accordance with NFPA 99, 1999 Edition. II/III
No deficiencies reported
View official state report (opens in a new tab)
No state licensure deficiencies were cited during this inspection.
No deficiencies reported
View official state report (opens in a new tab)
No state licensure deficiencies were cited during this inspection.
No deficiencies reported
View official state report (opens in a new tab)
No state licensure deficiencies were cited during this inspection.
3 deficiencies reported
View official state report (opens in a new tab)
3 state licensure deficiency citation(s) recorded.
minorCorrected Jul 2, 2019
Interior Finish and Furnishings. (D) All curtains and drapes in a licensed facility shall be certified or treated to be flame-resistant as defined in NFPA 101, 2000 edition. II
minorCorrected Jul 2, 2019
Protection from Hazards. (A) In assisted living facilities and residential care facilities licensed on or after November 13, 1980, for more than twelve (12) beds, hazardous areas shall be separated by construction of at least a one- (1-) hour fire-resistant rating. In facilities equipped with a complete fire alarm system, the one- (1-) hour fire separation is required only for furnace or boiler rooms. Hazardous areas equipped with a complete sprinkler system are not required to have this one- (1-) hour fire separation. Doors to hazardous areas shall be self-closing and shall be kept closed unless an electromagnetic hold-open device is used which is interconnected with the fire alarm system. When the sprinkler option is chosen, the areas shall be separated from other spaces by smoke-resistant partitions and doors. The doors shall be self-closing or automatic-closing. Facilities formerly licensed as residential care facility I or II, and existing prior to November 13, 1980, shall be exempt from this requirement. II
minorCorrected Jul 2, 2019
Complete Fire Alarm Systems. (A) All facilities shall have a complete fire alarm system installed in accordance with NFPA 101, Section 18.3.4, 2000 edition. The complete fire alarm shall automatically transmit to the fire department, dispatching agency, or central monitoring company. The complete fire alarm system shall include visual signals and audible alarms that can be heard throughout the building and a main panel that interconnects all alarm-activating devices and audible signals. Manual pull stations shall be installed at or near each required attendant ' s station and each required exit. I/II
No deficiencies reported
View official state report (opens in a new tab)
No state licensure deficiencies were cited during this inspection.
Neighborhood & resident support
Nearest hospital
Macon County Samaritan Memorial Hospital
1.2 mi · Macon, MO · Medicare 2/5 ★
FEMA hazard risk
Free resident advocacy
Missouri Long-Term Care Ombudsman Program
VA & dialysis access
Columbia MO VA Medical Center
56.4 mi · Columbia, MO · VA 4/5 ★
2.3 mi · 2/5 ★
Environment & mobility
County demographics
Call & tour checklist
Check off questions as you call or tour. Your progress stays private in this browser.
Verification & public records
Verify licensing, ratings, and inspection reports directly with each official source.
EveryPlace is an independent research directory. Information is compiled from public Medicare.gov, state licensing, Google Places, and street-level imagery sources. Some summaries, suggested questions, and pricing notes are AI-generated or AI-assisted and may contain errors or omissions. We do not accept payment for placement. Confirm all details directly with the community and official sources. Research Policy.
Keep exploring