See every facility — official ratings, family reviews, no referral fees.
Assisted Living

Courtyard at Crista Shores

1600 Nw Crista Shores Lane, Silverdale, WA 9838382 bedsLicensed & Active
Source: WA DSHS — view official record
Google rating
3.0/5

based on 2 Google reviews

Watch Courtyard at Crista Shores

Get an email when new inspections, ratings, or penalties are published for this facility.

We’ll only email you about this — no spam, unsubscribe anytime.

State Inspection History

State Inspections

Source: WA Dept. of Social & Health Services

5total
24deficiencies
Nov 20, 2025Fire

Initial inspection on 10/14/2025 resulted in 'Disapproved' status. A follow-up inspection on 11/20/2025 resulted in 'Approved' status, noting all previous violations were corrected.

Required emergency drillsIFC 405.2 2021

Fire drills missed on the 1st, 2nd, and 3rd quarter of 2025.

Extension CordsIFC 603.6 2021

Power strip going through the wall near battery charging area in maintenance shop.

Duct and Air Transfer OpeningsIFC 706.1 2018

Fire/smoke damper report from 9/16/24 shows deficiencies; need documentation of corrections.

Testing and MaintenanceIFC 903.5 2021

Missing documentation for 3-year dry system full flow trip test and annual forward flow test; sprinkler heads in kitchen area loaded with debris and missing escutcheon ring; heads over 10 years need sample test.

Power TestIFC 1031.10.2 2021

Facility failed to provide documentation showing 1.5 hour emergency lights and exit signs power test.

Abatement of Electrical HazardsIFC 603.2 2021

Exposed electrical wires in the ceiling of maintenance shop.

Appliance Connection to Building PipingIFC 606.4 2021

Kitchen appliances that are gas-fired need to be tethered to the wall.

Inspection, Testing and MaintenanceIFC 907.8 2021

Facility failed to provide annual fire alarm report.

Fire Door Inspection and TestingNFPA 80

Double doors by pool/spa room and door to Room 410 failed to latch.

May 6, 2025Inspection

A separate letter dated 07/24/2025 notes that Compliance Determination 63075 and 58380 are corrected and the facility meets requirements.

PetsWAC 388-78A-2620Corrected Apr 25, 2025

Veterinary examination for feline was outdated; updated on 04/25/2025.

Temperature and time control: Frozen foodWAC 246-215-03500
Temperature and time control: Hot and cold holdingWAC 246-215-03525
Training and home care aide certification requirementsWAC 388-78A-2474Corrected May 31, 2025

Failed to ensure 2 of 6 sampled staff (Staff B and C) completed required annual 12 hours of continuing education training.

Temperature and time control: Cooling methodsWAC 246-215-03520
Food sanitationWAC 388-78A-2305Corrected Apr 25, 2025

Hot food served in steam tray transported on cold open rack; corrected onsite to use hot carts.

Water supplyWAC 388-78A-2950Corrected Apr 28, 2025

Hot water in 3 of 9 resident rooms not maintained between 105F and 120F due to a flipped breaker; corrected onsite.

Jan 13, 2025Fire

Initial inspection on 2024-10-03 resulted in a 'Disapproved' status. A subsequent inspection on 2025-01-13 confirmed all violations noted during previous inspections have been corrected.

Required emergency drillsIFC 405.2 2021

Facility failed to conduct fire drills once per shift per quarter for the last 12 months.

Sprinkler systems testing and maintenanceIFC 903.5 2021

Fire department hydrostatic test needed. Missing/improper sprinkler heads: missing escutcheon in room 505 and kitchen locker room, 3 loaded heads in assisted living kitchen, and blocked head in exercise room #2.

Duct and Air Transfer OpeningsIFC 706.1 2018

Facility failed to provide documentation showing fire/smoke damper 4 year inspection.

Jul 11, 2024Fire

Inspection conducted by the Washington State Patrol Fire Protection Bureau in response to a complaint regarding an electrical fire.

Electrical fire in light fixture

Fire occurred in the bathroom of a resident unit. The fire suppression system did not activate. The area was evacuated, there were no injuries, and the fire department responded.

Dec 9, 2023Fire

The inspection on 10/09/2023 resulted in a 'Disapproved' status. A follow-up inspection on 12/09/2023 confirmed that all violations noted during previous related inspection(s) have been corrected.

Extinguishing System ServiceIFC 904.12.5.2Corrected Dec 9, 2023

Facility failed to provide documentation showing first and second semi-annual servicing of the kitchen suppression system.

Smoke Detector SensitivityIFC 907.8.3Corrected Dec 9, 2023

Facility failed to provide documentation showing smoke detectors sensitivity test.

Testing and MaintenanceIFC 903.5Corrected Dec 9, 2023

Facility failed to provide annual inspection report, annual forward flow test on the backflow, and five-year fire department connection hydrostatic test.

Fusible Link and Sprinkler Head ReplacementIFC 904.12.5.3Corrected Dec 9, 2023

Facility failed to provide documentation showing annual replacement of fusible links for the kitchen suppression system.

Contact

Get in Touch

Contact this facility directly and verify the details that matter most to your family.

References & Resources

EveryPlace is a research directory. Facility information is compiled from public sources — Medicare.gov, state licensing portals, Google Places, and publicly available street-level imagery. Listings do not constitute endorsement, recommendation, or advertisement, and we do not accept payment for placement. Families should verify all details directly with the facility and the original sources linked above before making any care decisions. See our Research Policy for our editorial standards, correction process, and image-removal policy.