Loading EveryPlace content…
Loading EveryPlace content…
State license
Active
MO DHSS
Google reviews
Not available
Public reviews not linked
Size & payment
96 residents
Confirm pricing & payment
Public records for this community are limited. Use the checklist below when you call or visit to confirm pricing, services, and openings.
| Monthly cost | Not published | Ask for the full monthly cost, including care fees and one-time charges. |
|---|---|---|
| Payment options | Ask directly | Payment details are not confirmed in our records. Ask about private pay, long-term care insurance, veterans benefits, and Medicaid waivers. |
| Size & availability | 96 residents | We don't publish live openings. Ask about current availability, waitlist length, and move-in timing. |
| Care & support | Assisted livingMemory care certified | Usually offers housing and help with everyday tasks, such as bathing and dressing. What to confirm about care levelsThis describes the licensed category. Ask how care plans adjust if mobility, nursing, or memory needs change over time. Read the family care guide → |
State licensing
12inspections
33deficiencies listed
No deficiencies reported
View official state report (opens in a new tab)
No state licensure deficiencies were cited during this inspection.
No deficiencies reported
View official state report (opens in a new tab)
No state licensure deficiencies were cited during this inspection.
11 deficiencies reported
View official state report (opens in a new tab)
11 state licensure deficiency citation(s) recorded.
minorCorrected Aug 5, 2025
The facility may admit or retain an individual for residency in an assisted living facility only if the individual does not require hospitalization or skilled nursing placement as defined in this rule, and only if the facility: (F) Completes a community based assessment conducted by an appropriately trained and qualified individual as defined in section (4) of this rule: 1. Time frame requirements for assessment shall be: B. At least semiannually; II
minorCorrected Aug 5, 2025
Each resident admitted to the facility, or his or her next of kin, legally authorized representative or designee, shall be fully informed of the individual's rights and responsibilities as a resident. These rights shall be reviewed annually with each resident, and/or his or her next of kin, legally authorized representative or designee, either in a group session or individually. II/III
minorCorrected Aug 5, 2025
The facility shall maintain a record in the facility for each resident, which shall include the following: (B) A review monthly or more frequently, if indicated, of the resident ' s general condition and needs; a monthly review of medication consumption of any resident controlling his or her own medication, noting if prescription medications are being used in appropriate quantities; a daily record of administration of medication; a logging of the medication regimen review process; a monthly weight; a record of each referral of a resident for services from an outside service; and a record of any resident incidents including behaviors that present a reasonable likelihood of serious harm to himself or herself or others and accidents that potentially could result in injury or did result in injuries involving the resident; III
minorCorrected Aug 5, 2025
Records shall be maintained upon receipt and disposition of all controlled substances and shall be maintained separately from other records, for two (2) years. (A) Inventories of controlled substances shall be reconciled as follows: 1. Controlled Substance Schedule II medications shall be reconciled each shift; II
minorCorrected Aug 5, 2025
Nonfood-contact surfaces of equipment shall be cleaned as often as is necessary to keep the equipment free of accumulation of dust, dirt, food particles and other debris. III
minorCorrected Aug 5, 2025
Waste containers used in food-preparation and utensil-washing areas shall be kept covered when not in actual use. III
minorCorrected Aug 5, 2025
Ventilation hoods and devices shall be designed to prevent grease or condensation from collecting on walls and ceilings and from dripping into food or onto food-contact surfaces. Filters or other grease-extracting equipment shall be readily removable for cleaning and replacement if not designed to be cleaned in place. III
minorCorrected Aug 5, 2025
The administrator shall maintain on the premises an individual personnel record on each facility employee, which shall include the following: (I) Written statement signed by a licensed physician or physician ' s designee indicating the person can work in a long-term care facility and indicating any limitations; III
minorCorrected Aug 5, 2025
Food, whether raw or prepared, if removed from the container or package in which it was obtained, shall be stored in a clean covered container except during necessary periods of preparation or service. Container covers shall be impervious and nonabsorbent except that linens or napkins may be used for lining or covering bread or roll containers. III
minorCorrected Aug 5, 2025
The facility shall screen residents and staff for tuberculosis as required for long-term care facilities by 19 CSR 20-20.100. II
minorCorrected Aug 5, 2025
Prior to allowing any person who has been hired in a full-time, part-time, or temporary position to have contact with any resident, the facility shall, or in the case of temporary employees hired through or contracted from an employment agency, the employment agency shall, prior to sending a temporary employee to a facility: (A) Request a criminal background check for the person, as provided in section 660.317, RSMo. Each facility shall maintain documents verifying that the background checks were requested, the date of each such request, and the nature of the response received for each such request. II
1 deficiency reported
View official state report (opens in a new tab)
1 state licensure deficiency citation(s) recorded.
minorCorrected Jan 10, 2025
The facility shall not admit or continue to care for residents whose needs cannot be met. If necessary services cannot be obtained in or by the facility, the resident shall be promptly referred to appropriate outside resources or discharged from the facility. I/II
1 deficiency reported
View official state report (opens in a new tab)
1 state licensure deficiency citation(s) recorded.
minor
In facilities that are constructed or have plans approved after July 1, 2005, electrical wiring shall be installed and maintained in accordance with the requirements of the National Electrical Code, 1999 edition, National Fire Protection Association, Inc., incorporated by reference, in this rule and available by mail at One Batterymarch Park, Quincy, MA 02269, and local codes. This rule does not incorporate any subsequent amendments or additions to the materials incorporated by reference. Facilities built between September 28, 1979 and July 1, 2005 shall be maintained in accordance with the requirements of the National Electrical Code, which was in effect at the time of the original plan approval and local codes. This rule does not incorporate any subsequent amendments or additions. In facilities built prior to September 28, 1979, electrical wiring shall be maintained in good repair and shall not present a safety hazard. All facilities shall have wiring inspected every two (2) years by a qualified electrician. II/III
No deficiencies reported
View official state report (opens in a new tab)
No state licensure deficiencies were cited during this inspection.
1 deficiency reported
View official state report (opens in a new tab)
1 state licensure deficiency citation(s) recorded.
minor
In facilities that are constructed or have plans approved after July 1, 2005, electrical wiring shall be installed and maintained in accordance with the requirements of the National Electrical Code, 1999 edition, National Fire Protection Association, Inc., incorporated by reference, in this rule and available by mail at One Batterymarch Park, Quincy, MA 02269, and local codes. This rule does not incorporate any subsequent amendments or additions to the materials incorporated by reference. Facilities built between September 28, 1979 and July 1, 2005 shall be maintained in accordance with the requirements of the National Electrical Code, which was in effect at the time of the original plan approval and local codes. This rule does not incorporate any subsequent amendments or additions. In facilities built prior to September 28, 1979, electrical wiring shall be maintained in good repair and shall not present a safety hazard. All facilities shall have wiring inspected every two (2) years by a qualified electrician. II/III
2 deficiencies reported
View official state report (opens in a new tab)
2 state licensure deficiency citation(s) recorded.
minorCorrected May 8, 2023
Each resident shall be free from abuse. Abuse is the infliction of physical, sexual, or emotional injury or harm and includes verbal abuse, corporal punishment, and involuntary seclusion. I
minorCorrected May 8, 2023
The administrator shall maintain on the premises an individual personnel record on each facility employee, which shall include the following: (K) Documentation of what the employee was instructed on during orientation training; III
1 deficiency reported
View official state report (opens in a new tab)
1 state licensure deficiency citation(s) recorded.
minorCorrected Sep 21, 2022
The administrator shall develop and implement a safe and effective system of medication control and use, which assures that all residents ' medications are administered by personnel at least eighteen (18) years of age, in accordance with physicians ' instructions using acceptable nursing techniques. The facility shall employ a licensed nurse eight (8) hours per week for every thirty (30) residents to monitor each resident ' s condition and medication. Administration of medication shall mean delivering to a resident his or her prescription medication either in the original pharmacy container, or for internal medication, removing an individual dose from the pharmacy container and placing it in a small cup container or liquid medium for the resident to remove from the container and self-administer. External prescription medication may be applied by facility personnel if the resident is unable to do so and the resident ' s physician so authorizes. All individuals who administer medication shall be trained in medication administration and, if not a physician or a licensed nurse, shall be a certified medication technician or level I medication aide. I/II
3 deficiencies reported
View official state report (opens in a new tab)
3 state licensure deficiency citation(s) recorded.
minorCorrected Sep 21, 2022
Staffing Requirements. (A) The facility shall have an adequate number and type of personnel for the proper care of residents, the residents ' social well being, protective oversight of residents and upkeep of the facility. At a minimum, the staffing pattern for fire safety and care of residents shall be one (1) staff person for every fifteen (15) residents or major fraction of fifteen (15) during the day shift, one (1) person for every twenty (20) residents or major fraction of twenty (20) during the evening shift and one (1) person for every twenty-five (25) residents or major fraction of twenty-five (25) during the night shift. I/II Time Personnel Residents 7 a.m. to 3 p.m. (Day)* 1 3-15 3 p.m. to 9 p.m. (Evening)* 1 3-20 9 p.m. to 7 a.m. (Night)* 1 3-25 *If the shift hours vary from those indicated, the hours of the shifts shall show on the work schedules of the facility and shall not be less than six (6) hours. III
minorCorrected Sep 21, 2022
Protective oversight shall be provided twenty-four (24) hours a day. For residents departing the premises on voluntary leave, the facility shall have, at a minimum, a procedure to inquire of the resident or resident ' s guardian of the resident ' s departure, of the resident ' s estimated length of absence from the facility, and of the resident ' s whereabouts while on voluntary leave. I/II
minorCorrected Sep 21, 2022
The facility may admit or retain an individual for residency in an assisted living facility only if the individual does not require hospitalization or skilled nursing placement as defined in this rule, and only if the facility: (H) Reviews the ISP with the resident, or legal representative of the resident, at least annually or when there is a significant change in the resident ' s condition which may require a change in services; II
10 deficiencies reported
View official state report (opens in a new tab)
10 state licensure deficiency citation(s) recorded.
minorCorrected Sep 29, 2021
Fire Drills and Emergency Preparedness. (A) All facilities shall have a written plan to meet potential emergencies or disasters and shall request consultation and assistance annually from a local fire unit for review of fire and evacuation plans. If the consultation cannot be obtained, the facility shall inform the state fire marshal in writing and request assistance in review of the plan. An up-to-date copy of the facility ' s entire plan shall be provided to the local jurisdiction ' s emergency management director. II/III
minorCorrected Sep 29, 2021
Exit Signs. (C) All required exit signs and directional indicators shall be positioned so that both normal and emergency lighting illuminates them. II/III
minorCorrected Sep 29, 2021
Complete Fire Alarm Systems. (E) Facilities shall test by activating the complete fire alarm system at least once a month. I/II
minorCorrected Sep 29, 2021
Interior Finish and Furnishings. (D) All curtains and drapes in a licensed facility shall be certified or treated to be flame-resistant as defined in NFPA 101, 2000 edition. II
minorCorrected Sep 29, 2021
Exits, Stairways, and Fire Escapes. (D) An " area of refuge " shall have- 1. An area separated by one- (1-) hour rated smoke walls, from the remainder of the building. This area must have direct access to the exit stairway or access the stair through a section of the corridor that is separated by smoke walls from the remainder of the building. This area may include no more than two (2) resident rooms; 2. A two- (2-) way communication or intercom system with both visible and audible signals between the area of refuge and the bottom landing of the exit stairway, attendants ' work area, or other primary location as designated in the written plan for fire drills and evacuation; 3. Instructions on the use of the area during emergency conditions that are located in the area of refuge and conspicuously posted adjoining the communication or intercom system; 4. A sign at the entrance to the room that states " AREA OF REFUGE IN CASE OF FIRE " and displays the international symbol of accessibility; 5. An entry or exit door that is at least a one and three-fourths inch (1 3/4") solid core wood door or has a fire protection rating of not less than twenty (20) minutes with smoke seals and positive latching hardware. These doors shall not be lockable; 6. A sign conspicuously posted at the bottom of the exit stairway with a diagram showing each location of the areas of refuge; 7. Emergency lighting for the area of refuge; and 8. The total area of the areas of refuge on a floor shall equal at least twenty (20) square feet for each resident who is blind or requires the use of a wheelchair or walker housed on the floor. II
minorCorrected Sep 29, 2021
Complete Fire Alarm Systems. (A) All facilities shall have a complete fire alarm system installed in accordance with NFPA 101, Section 18.3.4, 2000 edition. The complete fire alarm shall automatically transmit to the fire department, dispatching agency, or central monitoring company. The complete fire alarm system shall include visual signals and audible alarms that can be heard throughout the building and a main panel that interconnects all alarm-activating devices and audible signals. Manual pull stations shall be installed at or near each required attendant ' s station and each required exit. I/II 1. For facilities with a sprinkler system in accordance with NFPA 13, 1999 edition, smoke detectors interconnected to the complete fire alarm system shall be installed in all corridors and spaces open to corridors. Smoke detectors shall be no more than thirty feet (30') apart with no point on the ceiling more than twenty-one feet (21') from a smoke detector. I/II
minorCorrected Sep 29, 2021
In facilities that are constructed or have plans approved after July 1, 2005, electrical wiring shall be installed and maintained in accordance with the requirements of the National Electrical Code, 1999 edition, National Fire Protection Association, Inc., incorporated by reference, in this rule and available by mail at One Batterymarch Park, Quincy, MA 02269, and local codes. This rule does not incorporate any subsequent amendments or additions to the materials incorporated by reference. Facilities built between September 28, 1979 and July 1, 2005 shall be maintained in accordance with the requirements of the National Electrical Code, which was in effect at the time of the original plan approval and local codes. This rule does not incorporate any subsequent amendments or additions. In facilities built prior to September 28, 1979, electrical wiring shall be maintained in good repair and shall not present a safety hazard. All facilities shall have wiring inspected every two (2) years by a qualified electrician. II/III
minorCorrected Sep 29, 2021
Exits, Stairways, and Fire Escapes. (E) If it is necessary to lock exit doors, the locks shall not require the use of a key, tool, special knowledge, or effort to unlock the door from inside the building. Only one (1) lock shall be permitted on each door. Delayed egress locks complying with section 7.2.1.6.1 of the 2000 edition NFPA 101 shall be permitted, provided that not more than one (1) such device is located in any egress path. Self-locking exit doors shall be equipped with a hold-open device to permit staff to reenter the building during the evacuation. I/II
minorCorrected Sep 29, 2021
Trash and Rubbish Disposal. (A) Only metal or UL- or FM-fire-resistant rated wastebaskets shall be used for trash. II
minorCorrected Sep 29, 2021
General Requirements. (D) The department shall have the right of inspection of any portion of a building in which a licensed facility is located unless the unlicensed portion is separated by two- (2-) hour fire-resistant construction. No section of the building shall present a fire hazard. I/II
3 deficiencies reported
View official state report (opens in a new tab)
3 state licensure deficiency citation(s) recorded.
minorCorrected Aug 4, 2021
Protective oversight shall be provided twenty-four (24) hours a day. For residents departing the premises on voluntary leave, the facility shall have, at a minimum, a procedure to inquire of the resident or resident ' s guardian of the resident ' s departure, of the resident ' s estimated length of absence from the facility, and of the resident ' s whereabouts while on voluntary leave. I/II
minorCorrected Aug 4, 2021
The facility shall not admit or continue to care for residents whose needs cannot be met. If necessary services cannot be obtained in or by the facility, the resident shall be promptly referred to appropriate outside resources or discharged from the facility. I/II
minorCorrected Aug 4, 2021
Self-control of prescription medication by a resident may be allowed only if approved in writing by the resident ' s physician and included in the resident ' s individualized service plan. A resident may be permitted to control the storage and use of nonprescription medication unless there is a physician ' s written order or facility policy to the contrary. Written approval for self-control of prescription medication shall be rewritten as needed but at least annually and after any period of hospitalization. II/III
Neighborhood & resident support
Nearest hospital
St. Luke'S Hospital Of Kansas City
0.4 mi · Kansas City, MO · Medicare 5/5 ★
FEMA hazard risk
Free resident advocacy
Missouri Long-Term Care Ombudsman Program
VA & dialysis access
Kansas City VA Medical Center
3.6 mi · Kansas City, MO · VA 4/5 ★
0.6 mi · 2/5 ★ · Home dialysis
Specialists within 15 mi
Environment & mobility
County demographics
Call & tour checklist
Check off questions as you call or tour. Your progress stays private in this browser.
Verification & public records
Verify licensing, ratings, and inspection reports directly with each official source.
EveryPlace is an independent research directory. Information is compiled from public Medicare.gov, state licensing, Google Places, and street-level imagery sources. Some summaries, suggested questions, and pricing notes are AI-generated or AI-assisted and may contain errors or omissions. We do not accept payment for placement. Confirm all details directly with the community and official sources. Research Policy.